Galaxy VS UPS 150kW 400V for external batteries,

halogen-free cables, marine certified, Start-up 5×8

#GVSUPS150KMHS

Gambar Galaxy VS UPS 150kW 400V (GVSUPS150KMHS)

 

Specifications Galaxy VS UPS 150kW 400V (GVSUPS150KMHS)

Overview
– Presentation : Highly efficient, fast-to-deploy 150kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service and halogen-free cables. Marine certified.
– Lead time : Usually Ships within 2 Weeks

Main
– Main Input Voltage : 400 V 3 phases
– Other Input Voltage : 380 V, 415 V
– Main Output Voltage : 400 V 3 phases
– rated power in W : 150 kW
– Rated power in VA : 150 kVA
– Battery type :
> External battery system
> Li-Ion (Lithium-Ion)
> VRLA
– Provided equipment :
> Dust filter
> EcoStruxure IT ready (UPS)
> Installation guide
> Integrated network management
> Power modules ship installed
> Start-up service

General
– Bypass voltage tolerance : +/- 10 %
– Redundant : No

Physical
– Colour : White
– Height : 148.5 cm
– Width : 52.1 mm
– Depth : 84.7 cm
– Net weight : 290 kg
– USB compatible : No

Input
– Network frequency : 40…70 Hz
– Input voltage limits : 340…460 V 400 V
– Maximum input current : 270 A
– Max short time withstand current : 65 kA
– Input harmonic distortion : Less than 3 % for full load
– Load power factor : From 0.7 leading to 0.7 lagging without any derating

Output
– Maximum configurable power in W : 150 kW
– Output frequency
> 50 Hz sync to mains
> 60 Hz sync to mains
> 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
> 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
– Crest factor : 2.5
– Wave type : Sine wave
– Output voltage tolerance : +/-1% after 50ms
– Output harmonic distortion : < 1% linear load and < 5% non-linear load
– Output overload operation : 10 minutes at 125% and 60 seconds at 150%
– bypass type : Built-in static bypass
– Maximum configurable power in VA : 150 kVA

Conformance
– Standards :
> EN/IEC 62040-1
> EN/IEC 62040-2
> FCC part 15 class A
> IEC 60721-4-2 level 2M2
> UL 1778 5th edition

Environmental
– Ambient air temperature for operation : 0…40 °C
– Relative humidity : 0…95 % non-condensing
– Operating altitude : 0…3300 ft
– Ambient air temperature for storage : -25…55 °C
– Storage Relative Humidity : 10…80 % non-condensing
– Acoustic level : 68 dBA
– heat dissipation : 16900 Btu/h
– IP degree of protection : IP21

Batteries & Runtime
– Battery voltage : 480…576 V DC
– Discharge battery voltage : 384 V DC
– Max current discharge : 407 A
– Battery power in VAH : 0 VAh runtime
– Extended runtime : 0

Communications & Management
– control panel : Touch screen LCD user interface

Packing Units
– Unit Type of Package 1 : PCE
– Number of Units in Package 1 : 1
– Package 1 Height : 168 cm
– Package 1 Width : 99 cm
– Package 1 Length : 64 cm
– Package 1 Weight : 330 kg

Contractual warranty
– Warranty : 1 year on-site repair or replace with factory authorized Start-Up